Revision A 13 October 2011
2.6 Set-Up
2.6.1 Dry Contact Alarm
Dry contact alarms are located on the transmitter and receiver modules. When there is an alarm
condition the relay is energized. Examples of possible alarm causes might be over-temperature or a
power supply issue.
NORMALLY CLOSED NORMALLY OPEN
COMMON
ALARM
The dry contact alarm is a Form C contact with the following ratings:
Nominal Switching Capacity: 1 A 30 VDC, 0.3 A 125 VAX (resistive load)
Max. Switching Power: 30 W (DC), 37.5 VA (AC) (resistive load)
2.6.2 Firmware Upgrades
Firmware upgrades are available through Thinklogical
®
. Please call for technical assistance at:
1-203-647-8700.