TLX Matrix Switch SNMP Traps Manual 13 Rev. E - July, 2015
TLX320 HARDWARE ALARMS (Alarm Contacts)
Power Supply 1 Failure Begin and Clear Contact 1
TLX320 Power Supply 1 has failed (Begin) or is restored (Clear).
Begin OID: 1,3,6,1,4,1,17658,3,14,0,1
Clear OID: 1,3,6,1,4,1,17658,3,14,0,2
Objects:
1: tlxSwitchPSlabel
2: tlxSwitchPSstatus
3: sysContact
4: sysDescr
5: sysLocation
6: sysName
Power Supply 2 Failure Begin and Clear Contact 2
TLX320 Power Supply 2 has failed (Begin) or is restored (Clear).
Begin OID: 1,3,6,1,4,1,17658,3,14,0,3
Clear OID: 1,3,6,1,4,1,17658,3,14,0,4
Objects:
1: tlxSwitchPSlabel
2: tlxSwitchPSstatus
3: sysContact
4: sysDescr
5: sysLocation
6: sysName
Low Fan Speed Begin and Clear Contact 3
A fan in the Fan Tray has failed (Begin) or is restored (Clear).
Begin OID: 1,3,6,1,4,1,17658,3,14,0,5
Clear OID: 1,3,6,1,4,1,17658,3,14,0,6
Objects:
1: sysContact
2: sysDescr
3: sysLocation
4: sysName
Temperature Warning Begin and Clear Contact 4
The system has detected a temperature that is above the preset warning threshold (Begin) or is now below
the preset alarm threshold (Clear).
Begin OID: 1,3,6,1,4,1,17658,3,14,0,7
Clear OID: 1,3,6,1,4,1,17658,3,14,0,8
Objects:
1: sysContact
2: sysDescr
3: sysLocation
4: sysName